Skip to content
×
Try PRO Free Today!
BiggerPockets Pro offers you a comprehensive suite of tools and resources
Market and Deal Finder Tools
Deal Analysis Calculators
Property Management Software
Exclusive discounts to Home Depot, RentRedi, and more
$0
7 days free
$828/yr or $69/mo when billed monthly.
$390/yr or $32.5/mo when billed annually.
7 days free. Cancel anytime.
Already a Pro Member? Sign in here
Pick markets, find deals, analyze and manage properties. Try BiggerPockets PRO.
x
Results (1,575)
John Kim 1 boiler vs 3 boilers
13 November 2019 | 4 replies
I got quotes of $35,000, $40,000 and $35000.Cut out and remove the existing cast iron hot water boiler, both hot water heaters.Cut out and remove the existing 11/2"-21/2" supply and return heating mains that run from the mechanical room (back of the house) to the meter room (front of the house).Install 2- 9 port manifold stations in the mechanical for supplying heat to the cast iron radiators.Plumb the supply and return (home runs) 1/2" pex tubing for the cast iron radiators from the manifolds to the existing branch of risers in the basement ceiling.Pressure test all piping.Pipe new 11/4"x 50' gas piping from the meter room to the mechanical room.Pressure test gas piping.Install a HTP UFT 140 high efficient modulating condensing hot water boiler and a Turbomax 45 Reverse Indirect Tank (Buffer tank and Potable hot water) with near boiler piping and controls containing:The supply and return header piping from the UFT 140 boiler to the Turbomax 45 will be piped in a 2 pipe buffer tank configuration.Isolation drain and purge valves.Air and dirt magnet separators.High efficient ECM circulating pumps with isolation pump flanges.Hydronic expansion tank with support bracket.Back flow preventer and auto filer combo unit.Inline sediment and De-minerlized filter.Controls & Wiring:Low Water Cut Off.18- Manifold Actuators.Zone Control Box's.3-Thermostats with wireless sensors.Outdoor Sensor.Cold and Hot water potable water side:Isolation valves.Thermostatic mixing valve.Thermal expansion tank with support bracketPipe 3" Polypropylene and PVC flue and air intake piping from the boiler to the outside along with a thin low profile termination kit.Install a Condensate neutralizer pump and plumb the discharge tubing from the pump to the indirect stand pipe in the mechanical room.Pressure test all piping.Install and wire in all controls in the mechanical room.Power flush the system and remove any debris that is in the radiators and piping.Drain the water out of the entire system.Re-fill the entire heating system with De-mineralized water and power purge all the air out of the entire system.Set and adjust the flow meters on the manifolds as per radiators btu's output.Perform a combustion analysis on the boiler and make any adjustments if needed.
David Eisen Tenants owing a lot of rent and Forgiveness of Debt
4 December 2020 | 10 replies
If a creditor discharged a debt of $600 or more, you should receive a Form 1099-C from the IRS showing the amount of debt forgiven for that tax year.
Robert Howard Using REI for children's college fund.
3 May 2017 | 4 replies
@Robert Howard,I think the advantage to Brandon's strategy is that it uses something other than student loans which cannot be discharged in a bankruptcy.
Matt B. Why is everyone against paying for a seminar?
4 February 2014 | 186 replies
I have certainly learned a great deal about zero impact manufactured homes from the one industry expert that knows what they are talking about when it comes to solar powered, zero discharge, homes in the last two years, and may be soon putting that to profitable use as an investment.Again, I agree with Matt.
Latifa Al Latif Should I stay Or Should I Go?
24 February 2020 | 22 replies
I spent most of yesterday cutting upward into the bottom of a hundred-year-old cast iron toilet discharge with an angle grinder.
Alan Francis Drainage Issues... is a landscape architect the answer?
4 January 2021 | 13 replies
If it discharges next to your house, that might be your main issue. 
Bill Tyler Military Only Tenants
8 February 2016 | 13 replies
The only POSSIBLE way I could see this being an issue is if you denied housing to a veteran because they did not have an honorable discharge, and the less than honorable discharge was due to being homosexual or bisexual from back when that was banned.
Lee V. How to separate utilities between tenants??? Need help please
28 January 2022 | 68 replies
This was supposedly a safety issue; the meters have a pressure regulator that in the case of really excess pressure can relieve pressure by a slight discharge of gas - not a safe thing to do in an enclosed space.This year, the very same house, the gas company had to put in a new gas line from the street to the house due to a new higher pressure gas main being put into service.
Jim Shepard My tenant just filed for Chapter 13, now what?
22 July 2016 | 12 replies
It simply sets the debtor up for a repayment plan over 3 to 5 years and makes their life miserable and credit stays frozen over that time.A large percentage 80 to 90% never finish the plan to full discharge.
Craishia Millines Tenant Filed Bankruptcy
13 September 2019 | 11 replies
If it has been damaged in anyway - or if it appears they have been using it inappropriately (like sub-leasing, a business, etc) you can include that in your request with the court as another reason for termination.The good news here is that once a bankruptcy court orders them to pay - failure to do so will discharge their bankruptcy filing and you'll be back at eviction with full right to go after back rent due.