Skip to content
×
Pro Members Get
Full Access!
Get off the sidelines and take action in real estate investing with BiggerPockets Pro. Our comprehensive suite of tools and resources minimize mistakes, support informed decisions, and propel you to success.
Advanced networking features
Market and Deal Finder tools
Property analysis calculators
Landlord Command Center
ANNUAL Save 54%
$32.50 /mo
$390 billed annualy
MONTHLY
$69 /mo
billed monthly
7 day free trial. Cancel anytime
×
Try Pro Features for Free
Start your 7 day free trial. Pick markets, find deals, analyze and manage properties.
All Forum Categories
All Forum Categories
Followed Discussions
Followed Categories
Followed People
Followed Locations
Market News & Data
General Info
Real Estate Strategies
Landlording & Rental Properties
Real Estate Professionals
Financial, Tax, & Legal
Real Estate Classifieds
Reviews & Feedback

All Forum Posts by: John Kim

John Kim has started 12 posts and replied 43 times.

Post: Refinancing a 3 unit investment (NJ)

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

Has anyone beat 4.1% APR for a 75% cash out refinance? 750k mortgage balance.


property is in NJ

Post: From 2 to 18 Units ($1M+ in Real Estate) In 12 Months Using OPM

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

@Cory Iannacone

How did you get qualified for your new loans?  How did they calculate your debt to income ratio?  Did the banks use 75% of rents?

Post: From 2 to 18 Units ($1M+ in Real Estate) In 12 Months Using OPM

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

@Cory Iannacone

When you do a cash out refinance, how much are you available to cash out? 

Post: 1 boiler vs 3 boilers

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

Third question: Are you in a state where you are allowed to do RUBS to allocate the heat bills?

NJ. I believe it does allow RUBS.

Post: 1 boiler vs 3 boilers

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

Second question: how much would it cost to do it right and separate the heat systems? Would you have to drop their rents to make up for the fact that each of them now has to spend ~$1000 on heat a year? Or would you be able to charge similar or even higher rents because lots of people prefer to be able to set the heat where they want it? (edit: I can't count)

it would cost $10K more to have 3 separate boilers.  I would not drop rents. hopefully.  I don't see a scenario where rents go UP.

Post: 1 boiler vs 3 boilers

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

I got quotes of $35,000, $40,000 and $35000.



Cut out and remove the existing cast iron hot water boiler, both hot water heaters.
Cut out and remove the existing 11/2"-21/2" supply and return heating mains that run from the mechanical room (back of the house) to the meter room (front of the house).

Install 2- 9 port manifold stations in the mechanical for supplying heat to the cast iron radiators.
Plumb the supply and return (home runs) 1/2" pex tubing for the cast iron radiators from the manifolds to the existing branch of risers in the basement ceiling.
Pressure test all piping.

Pipe new 11/4"x 50' gas piping from the meter room to the mechanical room.
Pressure test gas piping.

Install a HTP UFT 140 high efficient modulating condensing hot water boiler and a Turbomax 45 Reverse Indirect Tank (Buffer tank and Potable hot water) with near boiler piping and controls containing:
The supply and return header piping from the UFT 140 boiler to the Turbomax 45 will be piped in a 2 pipe buffer tank configuration.
Isolation drain and purge valves.
Air and dirt magnet separators.
High efficient ECM circulating pumps with isolation pump flanges.
Hydronic expansion tank with support bracket.
Back flow preventer and auto filer combo unit.
Inline sediment and De-minerlized filter.

Controls & Wiring:
Low Water Cut Off.
18- Manifold Actuators.
Zone Control Box's.
3-Thermostats with wireless sensors.
Outdoor Sensor.

Cold and Hot water potable water side:
Isolation valves.
Thermostatic mixing valve.
Thermal expansion tank with support bracket
Pipe 3" Polypropylene and PVC flue and air intake piping from the boiler to the outside along with a thin low profile termination kit.
Install a Condensate neutralizer pump and plumb the discharge tubing from the pump to the indirect stand pipe in the mechanical room.
Pressure test all piping.
Install and wire in all controls in the mechanical room.

Power flush the system and remove any debris that is in the radiators and piping.
Drain the water out of the entire system.
Re-fill the entire heating system with De-mineralized water and power purge all the air out of the entire system.
Set and adjust the flow meters on the manifolds as per radiators btu's output.
Perform a combustion analysis on the boiler and make any adjustments if needed.

Post: 1 boiler vs 3 boilers

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

I have a 3 unit property in which there is only 1 thermostat across all 3 units.  It is an old hot water / cast iron radiator system.  I currently set the thermostat at 72 in the "coldest room" and pay about $3000/year in heat and hot water. Inevitably, someone always complains about being cold.

I have 2 options to update my heating system.


1)  Install 1 modcon boiler + indirect tank.  Plumb the supply and return (home runs) 1/2" pex tubing for the cast iron radiators. I would install BTU meters and charge each unit a fraction of their gas usage.  Each unit would have their own zone and thermostat.

Pros:  only 1 system to maintain. About 1/3 the cost ($30,000).  The total bill per tenant is probably cheaper due to modcon.

Cons: I have to deal with billing each tenant for their heat usage.

2) Install 3 hot water boilers.  Tenant would directly get billed for their gas/hot water usage.  Each unit would have their own thermostat.

Post: Line of credit for a rental property

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

@Keith N.

@Darrell Smith

@Cassi Justiz

What are the rates and fees for a pennfed HELOC?

Post: Soundproofing an upper lower duplex

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

@Jaysen Medhurst @Albert Olivarria

I have been contemplating the best and cheapest way to soundproofing my 3 floor apt building.

I do not want to demo the existing ceiling because it is very heavy plaster.

I believe the best solution without demolition is to:

1) add 2" metal channels to existing ceiling. You can add RC clips for better results.

2) add 2" pink insulation between the metal strips

3) add a new 1/2" drywall ceiling. Add 2 or 3 drywall layers for best results.

Read this test (look at test #5)

http://www.mjm.qc.ca/publications/en/177881_Floor-CeilingAssemblies.pdf

The most critical mistake that people make is not leaving a 1/8" gap between the new ceiling and the wall.  The new drywall ceiling should not touch the wall to prevent sound transfer.

Post: HELOC on investment properties

John KimPosted
  • Investor
  • Las Vegas, NV
  • Posts 43
  • Votes 7

@Jeff M.

I am also looking for HELOC on an investment property.

Does TD Bank offer HELOC for investment properties if I have less than 4 properties?