Dusty Corning
Houston CPA
21 August 2019 | 99 replies
@Kristi Buehring @Andrew Dao @Dominique Palmer @Loren Miner @Billy Dana @Tristan WilliamsSent!
Gerald Marshall
Annual Rent Increase
7 November 2016 | 13 replies
In mine, rent increases are common.
Emy Bernardo
Looking to invest in SW Florida or Treasure Coast
9 February 2022 | 44 replies
@Emy Bernardo I am house hacking in North Port Warm Mineral Springs area.
Jim K.
Window replacement, what do you do?
5 November 2019 | 77 replies
A lot of old coal miner houses in my area.
John Kim
1 boiler vs 3 boilers
13 November 2019 | 4 replies
I got quotes of $35,000, $40,000 and $35000.Cut out and remove the existing cast iron hot water boiler, both hot water heaters.Cut out and remove the existing 11/2"-21/2" supply and return heating mains that run from the mechanical room (back of the house) to the meter room (front of the house).Install 2- 9 port manifold stations in the mechanical for supplying heat to the cast iron radiators.Plumb the supply and return (home runs) 1/2" pex tubing for the cast iron radiators from the manifolds to the existing branch of risers in the basement ceiling.Pressure test all piping.Pipe new 11/4"x 50' gas piping from the meter room to the mechanical room.Pressure test gas piping.Install a HTP UFT 140 high efficient modulating condensing hot water boiler and a Turbomax 45 Reverse Indirect Tank (Buffer tank and Potable hot water) with near boiler piping and controls containing:The supply and return header piping from the UFT 140 boiler to the Turbomax 45 will be piped in a 2 pipe buffer tank configuration.Isolation drain and purge valves.Air and dirt magnet separators.High efficient ECM circulating pumps with isolation pump flanges.Hydronic expansion tank with support bracket.Back flow preventer and auto filer combo unit.Inline sediment and De-minerlized filter.Controls & Wiring:Low Water Cut Off.18- Manifold Actuators.Zone Control Box's.3-Thermostats with wireless sensors.Outdoor Sensor.Cold and Hot water potable water side:Isolation valves.Thermostatic mixing valve.Thermal expansion tank with support bracketPipe 3" Polypropylene and PVC flue and air intake piping from the boiler to the outside along with a thin low profile termination kit.Install a Condensate neutralizer pump and plumb the discharge tubing from the pump to the indirect stand pipe in the mechanical room.Pressure test all piping.Install and wire in all controls in the mechanical room.Power flush the system and remove any debris that is in the radiators and piping.Drain the water out of the entire system.Re-fill the entire heating system with De-mineralized water and power purge all the air out of the entire system.Set and adjust the flow meters on the manifolds as per radiators btu's output.Perform a combustion analysis on the boiler and make any adjustments if needed.
Juan Rango
Rental properties seem worse than traditional investments
22 October 2017 | 110 replies
There's dozens of tricks like that where a little investment in the property creates outsized returns (apartments->condos, selling mineral rights etc...).
Laura Krukowski
Does 1031 exchange work on raw land?
4 January 2024 | 14 replies
Have you looked into putting your 1031 into mineral rights?
Matt B.
Why is everyone against paying for a seminar?
4 February 2014 | 186 replies
If we need to drill deeper in Texas, you'll find that mineral rights and title coverage can have greater issues.
Nicole Masters
Rural Property - What to look out for?
30 November 2022 | 30 replies
Not sure this is a thing in California, but Id check on your mineral rights.
Jason Smith
Texas tax lien question
18 March 2022 | 4 replies
The 2 year redemption period in Texas is only for homestead exemptions, agricultural exemptions and severed mineral leases.