Skip to content
×
Pro Members Get
Full Access!
Get off the sidelines and take action in real estate investing with BiggerPockets Pro. Our comprehensive suite of tools and resources minimize mistakes, support informed decisions, and propel you to success.
Advanced networking features
Market and Deal Finder tools
Property analysis calculators
Landlord Command Center
ANNUAL Save 54%
$32.50 /mo
$390 billed annualy
MONTHLY
$69 /mo
billed monthly
7 day free trial. Cancel anytime
Pick markets, find deals, analyze and manage properties. Try BiggerPockets PRO.
x
All Forum Categories
All Forum Categories
Followed Discussions
Followed Categories
Followed People
Followed Locations
Market News & Data
General Info
Real Estate Strategies
Landlording & Rental Properties
Real Estate Professionals
Financial, Tax, & Legal
Real Estate Classifieds
Reviews & Feedback

All Forum Posts by: Vijay T.

Vijay T. has started 1 posts and replied 3 times.

Post: Chicago Multi-family HVAC Retrofit

Vijay T.Posted
  • Rental Property Investor
  • Chicago, IL
  • Posts 3
  • Votes 2

We are now about half way through the renovations on the 22 unit building. We are hoping to be completed in three more years renovating three units per year. 

- It quickly became apparent that the mini-split systems were out.  Perhaps they are the wave of the future, but in our circumstance they weren't right for the following reasons 1) the cost would have been about double of what we've paid for traditional forced air systems; 2) it would have required too much unsightly hardware and line sets all over the outside of the building; 3)they are designed for better insulated construction than this era of building provides. 

- We decided not to replace the existing boilers with high efficiency modulating condensing boilers.  The expense of these boilers is relatively high and the logistics of venting and providing air supply to them seemed too trouble some.  That coupled with the fact that all of the buildings heat, hot water and cooking gas would still be paid by us, made it so the savings from the boiler efficiency would not have been enough of an incentive. 

- Running individual gas meters and providing per-unit forced air was our ideal option, but we went against it for the following reasons: 1) the logistics of running new gas lines to each unit would be difficult and expensive; 2) that coupled with the fact that it was only a partial renovation of the building (not all the units at once) added to the difficulty; 3)given the time frame we had to complete the units we were working on, it was too risky to bring in the logistics of city and utility collaboration and inspections, to stay on schedule. 

- Regarding baseboard heat: given the upgrades we were doing (not fully high end but still nice), baseboard didn't provide the "amenities" we wanted the tenants to have e.g. air conditioning, programable thermostat, etc. 

- What we ended up doing was an electric forced air system.  This is like a traditional gas system but with an electric furnace (and AC).  My main objection to this system had been that electric heat is so much more expensive than gas, and that this would be a major problem in attracting long term tenants.  It's too early to tell if that is the case or not.  Last winter was very mild, and the financial difficulties of COVID have made it hard to assess causality.  We also went to an electric stove and hot water heater.  For the water heater, we were hoping to do tankless.  But electric tankless water heaters large enough to provide hot water for a family requires more amperage than we could reasonably get into each unit.  One downside of this all electric solution was that we had to upgrade the total service coming into the building, which was extremely expensive.  Still though from a mid to long term investment stand point, I think this was the best way to go given our reasonable options. 

We also have a four unit building with an expensive and inefficient steam boiler.  We really want to get rid of this.  Fortunately, each of those units already has its own gas meter. So the plan is to put in a central forced air furnace/AC into each individual unit.  The problem is that this is not an easy renovation to do while the units are occupied, and we have had long term tenants in each unit.  Also, the building really needs a major overhaul of electric and plumbing also, so the ideal solution would be to empty out the whole building and do something like a complete gut rehab. 

@J Scott

I own and have found both of your books extremely helpful!

My apologies if this topic is covered elsewhere. If so, feel free to point me to it.

We are about to acquire a 21 unit multi-family residential building in Chicago built c. 1970, and are exploring options for updating the HVAC.

There is currently a hot water boiler (three actually, and the original ones) for baseboard heat common to the whole building. Also, there are common domestic hot water tanks (gas paid by the owner), and a single gas meter so all tenants' cooking gas is paid by the owner as well.

We are exploring options for reducing the high gas-utility expense. Ideally, all of the tenants would pay for their own gas use (they are currently metered individually for electricity). The cost of doing so is the main question we are exploring.

The main unknown: the logistics/cost of running individual gas lines to each unit and giving each a separate gas meter.

Here are some of the options we are considering:

1) Keep the system basically as is, but update it for greater energy efficiency.

- Install two new high efficiency condensing boilers, and update windows and insulation for better heat loss performance.

PROS - a) minimally invasive; b) can provide 15-30% reduction in heating costs (we are told).

CONS - a)total gas expense is still paid by the landlord; b) individual units won't have individual control (except for a thermostat controlled shutoff valve for heat/water in each unit); c) AC would be available on with in wall/window units.

2) Try to individually meter each units' gas and provide each with a traditional forced air heating/cooling system.

PROS: a)gas expense could be completely removed for landlord (huge)- even tankless hot water could be installed in each unit; b) each unit would have their own climate control.

CONS: a) constructions costs of running new gas lines and soffiting sheet metal duct work. b) highly invasive with collateral construction costs; c) future costs of maintenance on multiple systems vs a single building-wide system.

3) An electric based heating system

- This is tricky in my mind because of the high cost of electric heat. We live in Chicago with harsh winters and expensive electric supply costs. I can't imagine shouldering that expense as a tenant, although I've been told that there are a number of nice buildings that utilize primarily electric heat.

- Also, we would have to run 220 lines to each unit.

4) Mini-split system.

PROS: a) minimally invasive; b) individual unit and in-unit-zone control; c) high efficiency

CONS: a) given Chicago's extreme cold snaps in winter, they cannot be (according to code) used as a "primary" heat source.

- One possible solution would be to keep the existing boiler/baseboard system for backup and/or use in extreme cold (possibly triggered by an outside temperature sensor). Then, of course, we haven't eliminated the heating gas expense, only reduced it. To what extent, is the question.

- Another solution would be to supply supplemental heat via electric baseboard heaters.

There a few moving parts to figure out here.

I'm sure that many people have experience with this very issue, and I'd love to hear about it!~

Thanks!

Post: Chicago Multi-family HVAC Retrofit

Vijay T.Posted
  • Rental Property Investor
  • Chicago, IL
  • Posts 3
  • Votes 2

Hello,


My apologies if this topic is covered elsewhere. If so, feel free to point me to it.

We are about to acquire a 10+ unit multi-family residential building in Chicago built c. 1970, and are exploring options for updating the HVAC.

There is currently a hot water boiler (three actually, and the original ones) for baseboard heat common to the whole building. Also, there are common domestic hot water tanks (gas paid by the owner), and a single gas meter so all tenants' cooking gas is paid by the owner as well.

We are exploring options for reducing the high gas-utility expense. Ideally, all of the tenants would pay for their own gas use (they are currently metered individually for electricity). The cost of doing so is the main question we are exploring.

The main unknown: the logistics/cost of running individual gas lines to each unit and giving each a separate gas meter.

Here are some of the options we are considering:
1) Keep the system basically as is, but update it for greater energy efficiency.
- Install two new high efficiency condensing boilers, and update windows and insulation for better heat loss performance.
PROS - a) minimally invasive; b) can provide 15-30% reduction in heating costs (we are told).
CONS - a)total gas expense is still paid by the landlord; b) individual units won't have individual control (except for a thermostat controlled shutoff valve for heat/water in each unit); c) AC would be available on with in wall/window units.

2) Try to individually meter each units' gas and provide each with a traditional forced air heating/cooling system.
PROS: a)gas expense could be completely removed for landlord (huge)- even tankless hot water could be installed in each unit; b) each unit would have their own climate control.
CONS: a) constructions costs of running new gas lines and soffiting sheet metal duct work. b) highly invasive with collateral construction costs; c) future costs of maintenance on multiple systems vs a single building-wide system.

3) An electric based heating system
- This is tricky in my mind because of the high cost of electric heat. We live in Chicago with harsh winters and expensive electric supply costs. I can't imagine shouldering that expense as a tenant, although I've been told that there are a number of nice buildings that utilize primarily electric heat.
- Also, we would have to run 220 lines to each unit.

4) Mini-split system.
PROS: a) minimally invasive; b) individual unit and in-unit-zone control; c) high efficiency
CONS: a) given Chicago's extreme cold snaps in winter, they cannot be (according to code) used as a "primary" heat source.
- One possible solution would be to keep the existing boiler/baseboard system for backup and/or use in extreme cold (possibly triggered by an outside temperature sensor). Then, of course, we haven't eliminated the heating gas expense, only reduced it. To what extent, is the question.
- Another solution would be to supply supplemental heat via electric baseboard heaters.


There a few moving parts to figure out here.

I'm sure that many people have experience with this very issue, and I'd love to hear about it!~

Thanks!