http://publicecodes.cyberregs.com/icod/irc/2009/icod_irc_2009_8_sec003.htm
this is straight off the International code 2009 1 and 2 family residential code page online . I emailed the city manager about some other questions. like since it will be owner occupied can I live in it while roofing, do I have to get a demolition permit, etc. I figured I'd wait til I got answers on that. Plus , verbal answers kind of bother me since I cant prove them. Emailing inspector would work though if i can get an answer. If I am misunderstanding this that would be GREAT!
R803 ROOF SHEATHING
R803.1 Lumber sheathing. Allowable spans for lumber used as roof sheathing shall conform to Table R803.1. Spaced lumber sheathing for wood shingle and shake roofing shall conform to the requirements of Sections R905.7 and R905.8. Spaced lumber sheathing is not allowed in Seismic Design Category D2.
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
RAFTER OR BEAM SPACING (inches) | MINIMUM NET THICKNESS (inches) |
24 | 5/8 |
48a | 11/2 T & G |
60b |
72c |
For SI: 1 inch = 25.4 mm.
a. Minimum 270 Fb, 340,000 E.
b. Minimum 420 Fb, 660,000 E.
c. Minimum 600 Fb, 1,150,000 E. |
R803.2 Wood structural panel sheathing.
R803.2.1 Identification and grade. Wood structural panels shall conform to DOC PS 1, DOC PS 2 or, when manufactured in Canada, CSA O437 or CSA O325, and shall be identified by a grade mark or certificate of inspection issued by an approved agency. Wood structural panels shall comply with the grades specified in Table R503.2.1.1(1). R803.2.1.1 Exposure durability. All wood structural panels, when designed to be permanently exposed in outdoor applications, shall be of an exterior exposure durability. Wood structural panel roof sheathing exposed to the underside may be of interior type bonded with exterior glue, identified as Exposure 1. R803.2.1.2 Fire-retardant-treated plywood. The allowable unit stresses for fire-retardant-treated plywood, including fastener values, shall be developed from an approved method of investigation that considers the effects of anticipated temperature and humidity to which the fire-retardant-treated plywood will be subjected, the type of treatment and redrying process. The fire-retardant-treated plywood shall be graded by an approved agency. R803.2.2 Allowable spans. The maximum allowable spans for wood structural panel roof sheathing shall not exceed the values set forth in Table R503.2.1.1(1), or APA E30. R803.2.3 Installation. Wood structural panel used as roof sheathing shall be installed with joints staggered or not staggered in accordance with Table R602.3(1), or APA E30 for wood roof framing or with Table R804.3 for steel roof framing.